Skip to content
1887
Volume 37, Issue 3
  • ISSN: 0032-1400

Abstract

The utilisation of advanced sensing techniques for detecting, indicating and monitoring toxic gases in industry and the environment is very important for health and safety. In this paper, the application of electrochemical, semiconductor, catalytic Field effect and catalytic gas sensors for the detection of toxic gases, and the role of platinum group metals in these devices, is discussed.

Loading

Article metrics loading...

/content/journals/10.1595/003214093X373146150
1993-01-01
2024-05-19
Loading full text...

Full text loading...

/deliver/fulltext/pmr/37/3/pmr0037-0146.html?itemId=/content/journals/10.1595/003214093X373146150&mimeType=html&fmt=ahah

References

  1. Hygien Institute, Chinese Academy of Medical Sciences, “Method for Detecting Poisonous Substance in Air”, China, 1974, 2 (Chinese) [Google Scholar]
  2. Altshuiler A. P. Advances in Chromatography”, 1968, p. 5 [Google Scholar]
  3. Zlatkis A. Sei. Tech. Arosp. Rep., 1976, 14, (22), 1 [Google Scholar]
  4. Nagashima K., and Suzuki S. Anal. Chim. Acta, 1984, 162, 153 [Google Scholar]
  5. Bottand B., and Jones T.A. Sera. Actuators, 1984, 5,(1), 43 [Google Scholar]
  6. Varfolomeev A. E., Volkov A. I., Eryshkin A. V, Malyshev V. V., Rasumov A. S., and Yakimov S. S Sens. Actuators, 1992, B7, 727 [Google Scholar]
  7. Kohl D. Sens. Actuators, 1989, 18, 73 [Google Scholar]
  8. Liu W.-G. Sens. Technoi., 1988, (4), 11 (Chinese) [Google Scholar]
  9. Omonagatoshihiko, Kihe mitsco, Keisokugijutsu, 1987, 15, (4), 47 (Japanese) [Google Scholar]
  10. Lei Y.-J. Electron. Elem. Mater., 1988, 7, (5), 7 (Chinese) [Google Scholar]
  11. Jones T. A., and Walsh P. T. Platinum Metals Rev., 1988, 32, (2), 50 [Google Scholar]
  12. Torvela H., Romppainen P., and Leppävuori S. Sens. Actuators, 1988, 14, (1), 19 [Google Scholar]
  13. Yan Sun Liang Sens. Technoi., 1990, (2), 1 (Chinese) [Google Scholar]
  14. Makoto E. Kogyo Zairgo, 1984, 32, (11), 39 (Japanese) [Google Scholar]
  15. Yamazoe N., Kurokawa Y., and Seiyama T. Sens. Actuators, 1989, 18, (1), 71 [Google Scholar]
  16. Morrison S. R. Sens. Actuators, 1987, 12, (4), 425 [Google Scholar]
  17. Weimar U., Schierbaum K. D., Gopel W., and Kowalkowski R. Sens. Actuators, 1990, B1, 93 [Google Scholar]
  18. Lundström I., Shivaraman M. S., Svensson C., and Lundkvist L. Appl. Phys. Lett., 1975, 26, 55 [Google Scholar]
  19. Lundström I., Shivaraman M. S., and Svensson C. J. Appl. Phys., 1975, 46, (9), 3876 [Google Scholar]
  20. Liu L. J., and Zhang W. X. Semicond. Technoi., 1988, (1), 50 (Chinese) [Google Scholar]
  21. Hornik W. Sens. Actuators, 1990, B1, 3522 [Google Scholar]
  22. Dobos K., Mokwa W., Zhang Y., Dura H.-G., and Zimmer G. Sens. Actuators, 1990, B1, 25 [Google Scholar]
  23. Lundström I., Spetz A., Winquist F., Ackelid V., and Sundgren H. Sens. Actuators, 1990, B1, 15 [Google Scholar]
  24. Peschke M., Lorenz H., Riess H., and Eisele I. Sens. Actuators, 1990, B1, 21 [Google Scholar]
  25. Sundgren H., Lukkari I., Carlsson R., and Wold S. Sens. Actuators, 1990, B2, 115 [Google Scholar]
  26. Lei Y.-J. Appl. Catal., 1991, 72, 33 [Google Scholar]
http://instance.metastore.ingenta.com/content/journals/10.1595/003214093X373146150
Loading
/content/journals/10.1595/003214093X373146150
Loading

Data & Media loading...

  • Article Type: Research Article
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error